HULK Metal Supply The Best Precast Concrete Accessories- Top Metal Manufacturer

product_banner
Magnetic Ferrule Insert Locators
Magnetic Ferrule Insert Locators

Magnetic Ferrule Insert Locators

Description:

HULK Metal magnetic ferrule insert locators fix UNC threaded inserts to steel forms without drilling or plugging the form face. Each locator is matched to an insert diameter, so the thread sits square to the form and stays clear of concrete during the pour. Nine sizes cover 1/4", 3/8", 1/2", 5/8", 3/4", 7/8", 1", 1-1/8" and 1-1/4" inserts, with part codes from HM-MFIL-00104 to HM-MFIL-10104. After stripping, the magnet is released with a 1/2" drive ratchet and the locator returns to the pallet for the next element. Locators are used on wall panels, columns, beams, stairs and other precast units cast on steel pallets or steel moulds.

share:
Inquiry Now
Catalog Download
  • Parameters
  • Features
  • Processes
  • Others
  • Blogs
  • Reviews
  • Top

Parameters of HULK Metal Magnetic Ferrule Insert Locators:

Magnetic Ferrule Insert Locators

CodeDL
HM-MFIL-001041/4"1/2"
HM-MFIL-003083/8"1/2"
HM-MFIL-001021/2"3/4"
HM-MFIL-005085/8"3/4"
HM-MFIL-003043/4"3/4"
HM-MFIL-007087/8"3/4"
HM-MFIL-100001"3/4"
HM-MFIL-101081-1/8"2"
HM-MFIL-101041-1/4"2"


Features of Magnetic Ferrule Insert Locators

  • Higher Quality Magnetic Ferrule Insert Locators:

    Features 1:


    A Reusable Setting Tool That Replaces Form Drilling


    Instead of drilling and later plugging the form face, the operator sets a locator on the steel pallet and lets the magnet hold it in place. The ferrule insert turns onto the locator nose, so the thread opening finishes flush with the form surface. After stripping, one turn with a 1/2" drive ratchet frees the locator for the next cast.


    Why Insert Position Decides Connection Quality


    Ferrule insert load tables are published for a defined installation: the insert set back 1/2" from the concrete face, the thread square to that face, and the insert held in position while the concrete is placed. A magnetic locator holds those conditions. The insert cannot drift or tilt while the vibrator works around it, and the thread opening stays clear of slurry and laitance because the form closes it off. A shifted insert shows up at the fixing stage. If the thread does not come through square, the bolt cannot reach full engagement, and published capacities assume the bolt is threaded in to the depth given for the size. Layout rules apply to the finished element as well: a minimum edge distance of 1.5 times the insert length and a minimum insert spacing of three times the insert length. Published shear values assume a plate or large washer bearing on the concrete surface.


    Features 2:


    Size Range and Form Compatibility


    Sizes run from 1/4" to 1-1/4" bolts, matching the ferrule inserts listed in the same catalog, with nine part codes from HM-MFIL-00104 to HM-MFIL-10104. Magnetic mounting needs a ferrous form face, so the locator suits steel pallets and steel moulds; timber and aluminium formwork call for a different setting method. The code suffix identifies the insert size, for example HM-MFIL-00102 for a 1/2" insert.


    Handling, Storage and Inspection Practice


    Release the locator with a 1/2" drive ratchet, turning the drive head instead of levering the body off the concrete with a bar. Keep the magnet face clean: concrete dust, curing compound and rust scale on the form cut the holding force, and a locator that slides while the vibrator runs usually points to a contaminated face or a thin form plate. Wipe the face before each set-up and check that the drive head and locating nose are not dented. Store locators dry and away from abrasive grit, and inspect them at the start of each production run. A cracked body, a stripped drive head or a magnet face that has lost its flatness is reason to withdraw the unit. The locator is a setting tool, not a load-bearing insert, so it comes out with the form. For thin form plate or heated curing cycles, ask the factory for magnet grade, holding force and temperature limits.


    You can get free samples to check whether they can meet the requirements.
    Get Free Samples
  • Magnetic Ferrule Insert Locators With Shorter Lead Time:

    Magnetic Ferrule Insert Locators

    Magnetic Insert Locators are used to mount UNC Threaded Inserts to a steel form instead of drilling holes. Magnets are removed from the concrete using a 1/2” drive ratchet. Available in 1/4”, 3/8”, 1/2”, 5/8”, 3/4”, 7/8”, 1”, 1-1/8”and 1-1/4” diameters.


    You can get a solution with shorter order delivery times and guaranteed quality and quantity.
    Get Your Free Solution
  • Magnetic Ferrule Insert Locators with Better Service:

    Custom Sizes and OEM Production


    Locator bodies and non-standard inserts can be produced to your drawings. OEM runs start from an approved sample, with the locator-to-insert pairing confirmed before production.


    Factory Quality Control


    Parts are made in an ISO 9001-certified workshop and inspected before dispatch. Ferrule inserts and fixing sockets pass tensile tests with a safety factor of 3 or more.


    Packaging and Delivery


    Choose wooden case, carton, bulk or individual packaging, or a custom pack. Shipments move by sea, air or land, with freight consulting and warehousing for mixed orders.


    Technical Support and After-Sales


    Engineers advise on size pairing, setback, edge distance and bolt engagement for your elements. The after-sales team handles technical, freight and quality questions.


    You can benefit from the comprehensive services of a dedicated client team.
    Contact Your Dedicated Service Team
  • Cost-controllable Magnetic Ferrule Insert Locators:

    No Holes in the Steel Form


    Magnetic mounting leaves the pallet face intact, so there is nothing to drill, plug or repair between casts. A layout change takes seconds: lift the locator, wipe the face and set it down again.


    Insert Position Held Through the Pour


    The locator keeps the ferrule insert flat to the form face at the published 1/2" setback while concrete is placed and vibrated, so the thread stays square and clear for the bolt.


    Ratchet Release and Reuse


    One turn of a 1/2" drive ratchet releases the magnet after stripping, and the locator goes back on the pallet for the next element. Nine part codes cover 1/4" through 1-1/4" inserts.


    You can leave a request and get a more suitable quotation.
    Get a Better Quotation

Procurement Process

  • 01
    In-depth understanding of your requirement.
  • 02
    In-depth understanding of your requirement.
  • 03
    In-depth understanding of your requirement.
  • 04
    In-depth understanding of your requirement.
  • 05
    In-depth understanding of your requirement.
  • 09
    In-depth understanding of your requirement.
  • 08
    In-depth understanding of your requirement.
  • 07
    In-depth understanding of your requirement.
  • 06
    In-depth understanding of your requirement.

Other Coil Inserts You Might Want to Know

Besides Standard Slab Coil Inserts, we also provide Straight Loop Coil Inserts, Expanded Coil Inserts, and Flared Thin Slab Coil Inserts. You can click on the corresponding picture for details. We will provide you with a full range of production services, and you can rest assured to place your order with us.

You Can Know About Magnetic Ferrule Insert Locators in Blogs

Here is what we can organize about the introduction, production, and quality inspection of magnetic ferrule insert locators, as well as some sharing from customers and details of our delivery. You can leave us a message if you want to share or get some content about Magnetic Ferrule Insert Locators.

Reviews

  • Martijn Van

    We set these magnetic ferrule insert locators on steel pallets for wall panels. Marking out takes minutes, and the insert threads come out clean on every element.

Write A Review
leave a message

If you have any questions or needs about the product, please fill in the following form and we will contact you as soon as possible.

Product:Magnetic Ferrule Insert Locators
Could I Have Your Name?
How Could I Contact You More Convenient?
You can upload parameters or drawings here.
Uploading +
Could you tell me the kind of support you hope to get?